Chapter 1 Introduction
Diabetes is a common global metabolic disorder, and in order to manage the disease well, we need to monitor blood sugar regularly. Blood glucose test strips are one of the essential diagnostic tools in the point-of-care testing system, and they convert the concentration of glucose in the body into quantifiable data for biochemical tests. The sensitivity of these strips is often determined by the accuracy of the enzymatic reaction, which is usually glucose oxidase or glucose dehydrogenase, and the consistency of their microfluidic structure. The manufacturing process will produce some random errors in the attachment of biomolecules and the preparation of reagents. Therefore, the regular quality inspection of blood glucose test strips should be done not only for the routine inspection of procedures but also to ensure the accuracy of diagnosis and to reduce the risk of adverse medical events caused by mistakes in the dosage of insulin [1].
Traditionally, strip quality tests are conducted at the manufacturer level for batch release; although the method is reasonable, it cannot effectively solve the problems of random degradation or potential defects during storage, transportation, or point-of-use. Thus, an independent, statistically sound post-market surveillance system is required. Sampling comparison is a relatively efficient way to conduct a thorough analysis. Based on the generalisation principle, it has been confirmed that taking samples randomly can estimate the overall quality of all products; thus, generalisation is not necessary for all products and is more economical in terms of cost and effort [7].
Based on statistical inference theory, the acceptable quality limit and sampling risk parameters are adjusted reasonably to control the probabilities of type I and type II errors. Operationally, the first step is to set the sampling plan according to the lot size, then carry out repeated measurements in an environment that can control the deviation of the strip, and then conduct a statistical hypothesis test to determine whether there is any significant difference. In practical application, it is quite crucial because it can give end-users and regulatory authorities a mathematically proven framework for verifying the continuous reliability of diagnostic consumables. It can directly meet the need for reducing the bias of glycemic measurement in clinic and thus protect the safety of patients [4]. Based on the above, this article will systematically study the performance of sampling contrast to control the quality of blood glucose test strips, illustrate its operating parameters, show its good ability to detect non-conformities in batches, and finally promote the revision of the clinical diagnosis guidelines.
Chapter 2 Sampling Comparison Experiment and Effect Analysis of Blood Glucose Test Strip Quality Control
2.1 Core Definition and Theoretical Basis of Blood Glucose Test Strip Quality Control
According to the standards of the global clinical diagnostic industry, the quality control of the blood glucose test strip is a systematic way to ensure that all produced strips can provide reliable results in clinical practice. It is necessary to strictly comply with the rules of sampling representativeness to ensure that the inspected samples can correctly reflect the heterogeneity of the entire batch, and the test results must be traceable and referable to the standard. The total error allowed for glucose monitoring is the limit of the clinical effect of these indicators, and according to current medical laboratory standards, it should be ±15% for glucose concentrations above 5.5 mmol/L. The quality control effect quantification metrics (non-conforming rate, coefficient of variation, etc.) are used to convert qualitative judgments into strict statistical indices for objective assessment of compliance.
The working principle of the enzyme-based blood glucose test strip is that glucose is oxidised by glucose oxidase or glucose dehydrogenase, and then this process is converted into an electrical signal. Enzyme coating quality will be the first to check if the catalytic activity is in all places of the reaction surface; reaction layer stability will be the second to ensure that the reagent will not degrade in the shelf life; anti-interference will be the last to prevent abnormal current signal changes caused by common endogenous interference substances such as red blood cells and ascorbic acid.
The basis for the theoretical support of sampling comparison for quality control assessment is based on the statistical sampling theory of non-conforming rate estimation in batch production. Using probabilistic acceptance sampling framework, one can mathematically determine the confidence interval of the true defect rate of a population with a finite representative sample and balance the risks for consumers and producers. Combined with the requirements for point-of-care glucose testing in clinical laboratories for quality control, which call for regular and structured verification of strip performance against reference assays, this is done. In addition, the error component model provides an assessment; systematic deviation arises from long-term manufacturing problems, such as non-uniform enzyme coating or reagent deterioration; random error comes from the natural randomness of the electrochemical reaction itself. Through comparison sampling to separate error elements, one can build a solid foundation for quality control in theory and use this to systematically identify defective strips before they are put into clinical use.
表1 Blood Glucose Test Strip QC Theories
2.2 Design of Sampling Comparison Experiment for Quality Control Assessment
2.2.1 Selection of test strip batches and sampling grouping criteria
The selection of test strip batches and the definition of sampling grouping criteria are the basis for the sampling comparison experiment; thus, they will serve as the basis for the subsequent analysis of quality control effects that are statistically reliable and have practical significance. We have chosen six different batches of commercial enzyme-based blood glucose test strips for this experiment. Based on the reason for selection, there are three different times for production: within one month after production, six months before the expiration date on the label, and one week before the expiration date on the label, so as to observe the changes in enzyme activity over the life cycle of the product. At the same time, two different storage conditions are also taken into account: the recommended temperature and humidity for storage according to the manufacturer's specifications, and an artificially created high-temperature environment that is often encountered in everyday life. The factorial selection matrix covers all aspects of ageing due to time and the impact of different environmental stresses on the performance of electrochemical biosensors.
After determining the batch selection, the stratified random sampling grouping standards are strictly applied. 120 test strips are randomly taken from each of the six batches. Then, they are divided into three groups: 40 in the routine unprocessed control group, 40 in the pre-use quality inspection intervention group, and 40 in the full-process enhanced quality control group. The stratified allocation ensures that the number of samples in each experimental condition is proportional. It should be noted that the grouping design will automatically exclude such disturbances as differences in the production lines of the test strips, differences in packaging specifications, and other factors that vary from batch to batch. The allocation of each batch of test strips, at the same time in life or storage, among the three groups of experiments should be carried out fairly, and the quality control intervention is an independent variable.
To guarantee the full transparency and traceability of the sampling framework, all basic metadata of the selected batches are carefully recorded. It contains the exact batch number, labelled expiry date, stated performance parameters such as bias and precision, and the continuously recorded storage history with temperature logs. Such detailed records can help us find the source of systematic errors in a timely manner, and at the same time, ensure the reproducibility of the experimental system so that it meets the requirements of strictness for biomedical engineering quality tests.
2.2.2 Setting of control parameters and experimental operation flow
The strict adjustment of the control parameters and the careful planning of the experimental process are important parts for judging the quality of the control effect of blood glucose test strips by sampling. In order to guarantee the metrological traceability and statistical validity of the evaluation, all standardized control parameters have been set in accordance with the requirements of ISO 15197:2013 for blood glucose monitoring in vitro diagnostic test systems. The ambient experimental conditions are fixed at 22 to 24 degrees Celsius and a relative humidity of 45% to 55%, thus removing any effects from thermodynamics or moisture on the enzymatic reaction kinetics of the test strips. As a reference standard, three representative clinically relevant concentrations of venous plasma glucose have been determined: hypoglycemic at 3.2 mmol/L, normal at 6.1 mmol/L, and hyperglycemic at 12.7 mmol/L. The above reference samples have been precisely calibrated by a certified biochemical analyser to ensure the accuracy of the baseline. In addition, in each test, the amount of sample is fixed at 10 microliters, so as not to be affected by variations in the volume of the sample. Before the experiment starts, all test strips with visible physical damage, such as scratches on the reaction layer or broken electrode contacts, will be systematically excluded to avoid hardware-induced systemic errors.
Based on the above strict parameters, follow the process flow of the experiment to maintain the consistency of the process. First, preheat all the test strips and test equipment to the ambient temperature of the experiment for 30 minutes, so that the internal electrochemical environment can be stable and the transient heat drift can be reduced. Next, refer to the calibration code provided by the manufacturer of the supporting blood glucose meter to adjust the firmware of the meter according to the characteristics of the specific reagent batch. After starting the test, all the operations of the blood glucose meter will be in accordance with the instructions for use. During the measurement process, record each measured glucose value and the corresponding test response time at the same time; that is to say, both the analytical output and the dynamic time history are recorded. To avoid subjective operation deviations and guarantee data objectivity, two independent experimenters will carry out a double-blind data recording. The dual verification protocol can prevent one-sided transcription errors and improve the epistemic reliability of the data set; thus, it is necessary for the subsequent comparison of quality control effects.
2.2.3 Data calibration and validity verification of sampling results
Data calibration and validity verification are the key ways to ensure that the statistical reliability and analysis results of the sampling comparison experiment are reliable. A series of processes will be used to systematically eliminate measurement errors and confirm that the underlying statistical assumptions for strict quality control are met. The raw sampling data will first be removed of the outliers. Data points that differ by more than three standard deviations from the average value of the group they belong to have been identified. Retain the extreme values only when there is no obvious non-random cause; if they are confirmed to be due to problems in the operation process, such as too small a sample size or improper insertion of strips, they will be removed to avoid artificially increasing the variance.
After removing outliers, perform Systemic bias calibration. The measured blood glucose values from each test strip are converted according to the reference values of a certified biochemical analyser. This step is essential for separating the intrinsic performance variance of the test strips from the fixed or proportional systemic errors caused by the proprietary algorithm or optical hardware of the glucose meter.
Based on the cleaned and calibrated data, a valid test scheme will be established to support the next comparative study. First, Shapiro-Wilk test is used to check if the distribution of the calibrated sampling data is normal; this method has relatively high statistical power in small to moderate sample size. Second, in order to guarantee the comparability among groups at the beginning, one-way analysis of variance (ANOVA) will be used to examine whether there is a statistically significant difference in the basic physical properties of the test strips (such as the thickness of the reaction layer and the uniformity of enzyme coating) among the different sampling groups before testing. Third, the non-response rate and invalid data rate of the samples are calculated precisely to determine whether the final valid sample size of each group meets the minimum statistical power requirement at the 95% confidence level. To ensure that any changes in quality control can be identified, a high degree of sensitivity should be maintained. In order to maintain the reproducibility of the research, all the excluded invalid data points and their reasons for being excluded according to the above rules are recorded in the experiment log; the data processing process has been kept open and transparent.
2.3 Comparative Analysis of Quality Control Effects Across Different Groups
In order to compare the effects of different groups' quality control, we must conduct a quantitative evaluation based on the following indicators: the absolute deviation rate of the reference glucose value, the within-batch coefficient of variation (CV) of test results, the pass rate that meets ISO 15197 accuracy requirements, the number of non-conforming test strip units detected, and the total error rate of testing. The above indicators will be evaluated systematically for three different glucose concentration levels (hypoglycemic, euglycemic, and hyperglycemic) in the routine control group and the two enhanced intervention groups. First, the descriptive statistical results of all measured data in each group are given. By means of tables and box plots to show the distribution of the deviation in test results, it can be seen that the central tendency and dispersion of the errors in the measurement are relatively small, and the enhanced intervention plan can help reduce these errors.
In order to verify whether there is a statistically significant difference in performance, a variety of inferential statistics have been conducted. A paired t-test will be used to compare the average deviation of the routine control group with that of each enhanced intervention group, assuming that the paired differences are normally distributed. In addition, the non-parametric Mann-Whitney U test is also used to test whether there are significant differences in quality control performance without the assumption of normality, and thus to confirm that there is a statistically significant difference in quality control performance. The consistency of the parametric and non-parametric results will add more evidence that the enhanced quality control scheme has been effective.
In addition to the overall comparison among groups, a stratified comparison is needed to analyse the control effect under different production batches and storage conditions. The stratified classification can help us determine which types of batches and which specific environmental stressors will be more easily corrected by increasing the quality control. For example, test strips from older production batches or those stored under high temperature and high humidity are prone to degradation. The stratified analysis can show that enhanced intervention groups have disproportionately reduced non-conformities in these vulnerable sub-populations and thus separate the interaction effects of storage conditions and production variability on strip stability.
Finally, the practical application value of all these quality control schemes for clinical institutions and individual users will be judged based on the cost-effectiveness ratio of each plan. Based on the incremental costs of enhanced sampling interventions and the amount of decline in the total testing error rate and the number of non-conforming units, a general economic evaluation has been conducted. Based on this ratio, it will be determined whether the marginal improvement in diagnostic accuracy is worth the additional resource consumption and provide a theoretical basis for choosing appropriate quality control measures in resource-poor clinical settings.
2.4 Discussion of Key Factors Influencing Test Strip Quality Control Performance
The comparative analysis will examine the reasons for the final quality control of blood glucose test strips from both internal and external aspects. The inherent factors of the test strip batch, such as its shelf life, enzyme coating uniformity in production, and packaging sealing performance, are the most important ones. Based on the basic principles of reactions, glucose oxidase or glucose dehydrogenase catalyses the oxidation of blood sugar, thus producing an electric current that is proportional to the amount of glucose. As the shelf life shortens, the immobilised enzyme will denature, thereby reducing the catalytic reaction rate and leading to a consistent negative error in the measured values. Similarly, microscopic non-uniformity in enzyme coating will change the effective electrochemical active surface area and introduce random measurement errors; otherwise, poor packaging sealing will allow moisture and oxygen from the environment to enter and inactivate the mediator prematurely, thus distorting the electron transfer efficiency. Extrinsic operational factors include carrying out pre-use visual inspection and performance verification, adding storage condition monitoring before use, etc., as well as the operating proficiency of personnel who perform quality control checks. If we do not check for defects before use, we might apply the wrong strip. Without performance testing, problems in the batch will not be found. In addition, not monitoring storage conditions will speed up the above enzymatic degradation pathway. The level of operator skill is directly related to the accuracy of sample volume; if the sample volume is too small, it will not meet the stoichiometric proportion required for the complete enzymatic reaction and will produce an incorrect low signal. The results are consistent with what has been reported in the literature that enzymatic decay and environmental factors harm electrochemical biosensors. However, this study shows that there is a new finding: the combined effect of extrinsic storage monitoring and inherent packaging performance has a much larger impact on quality control variation than either of them alone; this effect was often underestimated in previous models. Although it has made some progress, there are still some problems in this paper.
This study is designed to only examine test strips based on the principle of enzymatic detection and exclude the non-enzymatic detection mode, such as direct electrochemical oxidation or noble metal nanoparticle-based sensors. Because non-enzymatic mechanisms bypass the biocatalytic pathway, they have very different degradation rates and interference patterns. Therefore, the established relationships between enzymatic denaturation, coating uniformity and quality control performance are only applicable to enzymatic electrochemical test strips and cannot be extended to non-enzymatic platforms without additional research.
Chapter 3 Conclusion
A systematic study is conducted on the use of sampling comparison to control quality in blood glucose test strips, and some results with important value for industry and medical diagnosis are obtained. The basic idea is that, based on statistical inference, a relatively small number of well-selected batches from the production batch are chosen for comparison with the reference standard, and the overall quality of all products in the population is thus inferred. The core principle is that deviations in electrochemical reactivity and enzymatic consistency, which are inherent to mass-produced biosensors, will be reflected as changes in the sampled current signal. Set a strict acceptance limit, and use the sampling comparison method to determine whether the lot is qualified; thus, the reliability of the glycemic reading is ensured. The operation route should have strict rules; determine the reasonable tolerance limit, choose a suitable number of samples based on hypergeometric or binomial distribution, conduct parallel testing at a certain concentration of blood glucose, and then perform a comparative statistical analysis (Bland-Altman plot or paired t-test) [6]. Based on the above, it can be concluded that this process has significantly reduced the risk of systematic errors across the entire batch, such as bias and imprecision, which are relatively small but may impact the accuracy of insulin dosage decision-making. The significance of this method in practice should be emphasised. In manufacturing, it does not require an expensive test due to all-encompassing inspection, and it can also comply with international metrological standards. Due to the above quality control, there will be no medical issues caused by the inaccuracy of this strip, and thus hypoglycaemia or hyperglycaemia will not occur. It is also revealed in this paper that the sensitivity of the sampling comparison is subject to the representativeness of the samples selected and the accuracy of the reference glucometer system. Although the approach can identify large-scale production problems, the resolution of small-scale deviations needs to be calibrated constantly with traceable reference materials. Finally, the research shows that sampling comparison can be employed in biomedical diagnostic devices as a means of continuous quality improvement. The above conclusion shows that only by strictly following the operationalised sampling plan can the diagnostic accuracy of blood glucose test strips at all distribution levels be ensured [3].
References
[1]张苏琳, 卞蓉蓉, 吴莉. 220例血糖试纸不良事件风险分析[J]. 中国医疗器械信息, 2018, 24(23): 3.
[2]Zhou, Gao, Liu, Haibin. Commercial Translation of Electrochemical Biosensors: Supply Chain Strategy, Scale-Up Manufacturing, and Regulatory-Quality Considerations.[J]. Biosensors, 2026, 16(2).
[3]Bybin, V A, Bykova, N M, Kharitonova, E A. [Study of accuracy assessment of the Gmate LIFE blood glucose monitoring system].[J]. Problemy endokrinologii, 2026, 71(6): 67-75.
[4]Lu, Mingxin, Cheng, Jie, Lei, Qinyao. A High-Precision Screen-Printed Glucose Sensor with In Situ Impedance-Based HCT Correction and Temperature Compensation.[J]. Biosensors, 2026, 16(4).
[5]Darmau, Bastien, Mishyn, Vladyslav, Elloumi, Abir. Photocrosslinked dextran hydrogel coatings with FAD-glucose dehydrogenase for continuous glucose monitoring in complex media: Key role of methacrylation degree on bioelectrocatalytic activity and sensor stability.[J]. Biosensors & bioelectronics, 2026, 303: 118575.
[6]Han, Jingyi, Guo, Jinhong, Cheng, Jie. Disposable stepped radial microfluidic test card for multiplex electrochemical whole-blood analysis.[J]. Biosensors & bioelectronics, 2026, 314: 119187.
[7]Boroomand, Saeed, Binder, Simon, Leber, Moritz. Optical imaging of microfluidic integrated smart hydrogels for research and sensing applications.[J]. Sensors and actuators. B, Chemical, 2025, 441.
[8]Pudineh Moarref, Mokarrameh, Black, Wanda, Chen, Yu. Performance of New Roche Cobas Pulse Glucose Meter Against Potential Interfering Substances and Hematocrit Variations.[J]. Diagnostics (Basel, Switzerland), 2026, 16(9).
同组范文继续核对
回本组目录 →- 01 Aesthetic Education Courses in Campus Exhibition Halls: A Stratified Sampling Study of Aesthetic Perception
- 02 Yinyang Season Texts in Qin-Han Bamboo Slips: A Textual Analysis of Temporal Thought
- 03 Medical Breathable Tape Questionnaire Evaluation of Adhesion Strength in Dermatology Dressing Rooms
- 04 Shared Picture-Book Reading in Suburban Primary English: An Action-Research Exploration of Interest Fit
- 05 Tour Guide Group Registers Qualitative Analysis on Complaint Reduction Optimization Mechanism Analysis
- 06 Brownian Motion Trajectory Size Correlation Fluctuation Analysis Using Tracer Method